MEK MCQ · Set 8 of 10

MEK MCQ Set 8: Boilers & Steam

30 practice questions on boilers & steam. Tap an answer to see the result and a short explanation.

By Shashwat Bind · Last updated October 28, 2026 · Original practice questions, not past exam papers

Answered 0 of 30 · Score 0
Q1. A boiler's main function is to:
Q2. An exhaust gas boiler uses the heat of:
Q3. The safety valve on a boiler:
Q4. The water level in a boiler is checked on the:
Q5. Priming in a boiler is:
Q6. Boiler feed water is treated to prevent:
Q7. Superheated steam is steam that is:
Q8. A very low boiler water level is dangerous because:
Q9. A condenser in a steam plant:
Q10. A boiler feed pump:
Q11. In a water tube boiler:
Q12. In a fire tube boiler:
Q13. Which of these is a boiler mounting?
Q14. Boiler blowdown is carried out to:
Q15. Surface blow removes:
Q16. Boiler water is kept slightly alkaline to:
Q17. An oxygen scavenger is added to:
Q18. The hotwell collects:
Q19. A steam trap:
Q20. An economiser heats the:
Q21. A flame failure device:
Q22. The furnace is purged before lighting to:
Q23. Soot on exhaust gas boiler tubes can lead to:
Q24. A high chloride test result in boiler water indicates:
Q25. The boiler burner:
Q26. Dry steam is steam that contains:
Q27. Boiler safety valves are set to lift at:
Q28. On ships, steam is often used for:
Q29. Feeding cold water suddenly into a hot boiler can cause:
Q30. A pressure gauge on a boiler shows the:
Answer key and explanations
  1. A boiler's main function is to:
    Answer: B. Generate steam by heating water — Heat from fuel or exhaust turns feed water into steam.
  2. An exhaust gas boiler uses the heat of:
    Answer: B. The main engine exhaust gases — It recovers waste heat to make steam.
  3. The safety valve on a boiler:
    Answer: D. Lifts to release steam when pressure exceeds the set limit — It is the last protection against over-pressure.
  4. The water level in a boiler is checked on the:
    Answer: A. Gauge glass — Level gauges show whether the boiler has enough water.
  5. Priming in a boiler is:
    Answer: C. Carry-over of water droplets with the steam — Priming can damage steam machinery.
  6. Boiler feed water is treated to prevent:
    Answer: B. Scale and corrosion — Chemical treatment keeps heating surfaces clean and protected.
  7. Superheated steam is steam that is:
    Answer: A. Heated above the saturation temperature for its pressure — It carries more heat and contains no moisture.
  8. A very low boiler water level is dangerous because:
    Answer: D. Exposed heating surfaces can overheat and fail — Burners must be shut off and the cause found.
  9. A condenser in a steam plant:
    Answer: A. Turns exhaust steam back into water — The condensate is returned to the system as feed water.
  10. A boiler feed pump:
    Answer: B. Supplies water to the boiler against boiler pressure — It must overcome the pressure inside the boiler.
  11. In a water tube boiler:
    Answer: A. Water flows inside the tubes and hot gases pass outside — Water tube boilers can produce high pressure steam.
  12. In a fire tube boiler:
    Answer: A. Hot gases pass through tubes surrounded by water — Fire tube boilers are simple and robust.
  13. Which of these is a boiler mounting?
    Answer: C. Safety valve — Mountings include safety valves, gauge glasses and stop valves.
  14. Boiler blowdown is carried out to:
    Answer: D. Remove concentrated dissolved solids and sludge — It controls the water quality.
  15. Surface blow removes:
    Answer: C. Scum or oil floating on the water surface — It helps prevent priming.
  16. Boiler water is kept slightly alkaline to:
    Answer: A. Reduce corrosion — Alkaline water protects steel surfaces.
  17. An oxygen scavenger is added to:
    Answer: B. Remove dissolved oxygen from feed water — Oxygen causes pitting corrosion.
  18. The hotwell collects:
    Answer: B. Condensate from the condenser — It supplies the feed system.
  19. A steam trap:
    Answer: A. Passes condensate but holds back steam — It saves steam energy.
  20. An economiser heats the:
    Answer: D. Feed water using waste heat from exhaust gas — It improves efficiency.
  21. A flame failure device:
    Answer: B. Shuts off the fuel supply if the flame goes out — It prevents unburnt fuel collecting in the furnace.
  22. The furnace is purged before lighting to:
    Answer: D. Remove unburnt gases and avoid an explosion — Purging is done with air.
  23. Soot on exhaust gas boiler tubes can lead to:
    Answer: D. Reduced heat transfer and a risk of soot fire — Regular soot blowing is needed.
  24. A high chloride test result in boiler water indicates:
    Answer: D. Salt contamination — A condenser leak is a possible source.
  25. The boiler burner:
    Answer: C. Atomises the fuel and mixes it with air — Proper atomising gives clean combustion.
  26. Dry steam is steam that contains:
    Answer: A. Little or no moisture — Wet steam can damage turbines and pipes.
  27. Boiler safety valves are set to lift at:
    Answer: A. A pressure slightly above working pressure within the permitted limit — Their setting is checked by the surveyor.
  28. On ships, steam is often used for:
    Answer: B. Heating fuel, tank cleaning and accommodation — Heating systems need steam.
  29. Feeding cold water suddenly into a hot boiler can cause:
    Answer: D. Thermal stress and damage — Feed water is added carefully.
  30. A pressure gauge on a boiler shows the:
    Answer: D. Steam pressure — Operators watch it continually.

All MEK sets

Related reading

Rules and syllabus change; confirm with DG Shipping and your institute. See our disclaimer. Found a wrong answer? Tell us.

Author: Shashwat Bind

Founder, LearnGenZ.in | Merchant Navy career mentor

Last updated: October 28, 2026. See our editorial & corrections policy.